Product Center
Special valve for coal gangue conveying
It is suitable for opening and closing the inlet and outlet of gases and slag in dry ash systems at power plants, and also applicable to pipelines carrying abrasive, corrosive media, powders, flue gases, and other such media in industries such as mining, steel, papermaking, and petrochemicals.
Product Category:
Keywords:
Special valve for coal gangue conveying
Hotline:
Scope of Use
It is suitable for opening and closing the inlet and outlet of gas and slag in dry ash systems at power plants, and also applicable for opening and closing pipelines carrying abrasive, corrosive media, powders, flue gases, and other such media in industries such as mining, steel, papermaking, and petrochemicals.
Installation and Usage Tips
1. Before installation, carefully read these instructions and verify the valve model, nominal diameter, and technical specifications.
2. Welding flanges immediately after installing valves is strictly prohibited. The installation distance for valves pre-reserved in the pipeline should be appropriate, and gaskets must be added on both sides of the flange.
3. The centers of the two pipelines and the center of the valve’s bore should be coaxial, and the flange surfaces must be flat. Significant deviations in the flange surfaces are not permitted to ensure proper clamping and normal operation of the valve. When tightening the bolts, ensure that the tightening is uniform and symmetrical.
Product Features
1. The material inlet is fully open with no obstructions.
2. Excellent wear resistance and long service life.
3. For the special operating conditions of coal-cinder conveyance, the valve seat is designed with a sloped interior surface to prevent coal cinders from accumulating and facilitate valve closure. The lower valve disc is designed in a strip-like shape to enable the valve to open fully.
4. Compact structure and easy installation.
5. Self-adjusting sealing packing device.
Main Technical Parameters
Nominal pressure: 1.0 MPa
Medium temperature: 150~450℃
Strength test: 1.5 MPa
Sealing test: 1.1 MPa

Common Faults and Troubleshooting Methods
|
Failure |
Reason |
Exclusion method |
|
The valve is not sealing. |
There's a foreign object lodged. |
Remove foreign objects |
|
Sealing pair damaged |
Replace |
|
|
There is a leak at the flange joint. |
Bolts are tightened unevenly. |
Tighten the bolts evenly. |
|
Flange working surface damage |
Trim the flange working surface |
|
|
Gasket damage |
Replace the gasket. |
|
|
The valve cannot be opened or closed. |
Loose or failed transmission components |
Adjust or replace damaged parts. |
|
Insufficient air pressure, severe air leakage |
Inspect and repair the gas supply pipeline. |
|
|
Pneumatic component aging and failure |
Replace the damaged pneumatic components. |
|
|
Dust accumulation in the valve cavity |
Blow air into the valve through the purge port to remove dust. |
Size Parameter Table
|
Model |
Phi D1 |
ΦD2 |
n-M |
L |
|
DN150 |
280 |
240 |
8-M20 |
138 |
|
DN200 |
335 |
295 |
8-M20 |
138 |
|
DN250 |
390 |
350 |
12-M20 |
138 |
|
DN300 |
435 |
395 |
12-M20 |
138 |
Previous page