Product Center
RDV Rotary Disc Gate Valve
The RDV rotary disc gate valve operates by rotating the valve disc via a rotating shaft, ensuring that the valve’s opening and closing motion is rotational. The piston rod of the pneumatic actuator does not come into direct contact with the medium, thereby extending the actuator’s service life. The sealing pair is made of wear-resistant materials such as hard metals and ceramics, which offer excellent mechanical and wear resistance properties. This addresses the issue of sealing surfaces being easily eroded by material abrasion and having a short service life, resulting in a longer overall lifespan. Consequently, the valve delivers ideal operational performance and economic benefits to users, facilitates equipment maintenance and operational adjustments, and significantly enhances the overall safety and cost-effectiveness of system operation.
Product Category:
Keywords:
RDV Rotary Disc Gate Valve
Hotline:
Product Overview
The RDV rotary disc gate valve operates by rotating the valve disc via a rotating shaft, ensuring that the valve’s opening and closing motion is rotational. The piston rod of the pneumatic actuator does not come into direct contact with the medium, thereby extending the actuator’s service life. The sealing pair is made of wear-resistant materials such as hard metals and ceramics, which offer excellent mechanical and wear resistance properties. This addresses the issue of sealing surfaces being easily eroded by material abrasion and having a short service life, resulting in a significantly longer operational lifespan. Consequently, the valve delivers ideal performance and economic benefits to users, facilitates equipment maintenance and operational adjustments, and markedly enhances the overall safety and cost-effectiveness of system operation.
Scope of Use
Suitable for discharge and switching valves in dry ash systems at power plants, as well as for applications in mining, steelmaking, papermaking, petrochemicals, and other industries involving abrasive, corrosive media, powders, flue gases, and similar substances in pipelines.
Instructions for Compiling RDV Gate Valve Model Numbers

|
Valve bore designation |
||
|
DN50:01 |
DN65:02 |
DN80:03 |
|
DN100:04 |
DN125:05 |
DN150:06 |
|
DN200:08 |
DN250:10 |
DN300:12 |
Features
1. The material inlet features full-flow without any obstructions, resulting in fewer instances of ash jamming and accumulation.
2. Excellent wear resistance and long service life.
3. Compact structure and easy installation.
Main Technical Parameters
Nominal pressure: 1.0 MPa
Medium temperature: ≤400℃
Strength test: 1.5 MPa
Sealing test: 1.1 MPa
Installation and Usage Tips
1. Before installation, carefully read this instruction manual and verify the valve model, nominal diameter, and technical specifications.
2. Welding flanges immediately after installing valves is strictly prohibited. The installation distance for valves pre-reserved in the pipeline should be appropriate, and gaskets must be added on both sides of the flange.
3. The centers of the two pipelines and the center of the valve’s bore should be coaxial, and the flange surfaces must be flat. Significant deviations in the flange surfaces are not permitted to ensure proper clamping and normal operation of the valve. When tightening the bolts, ensure that the tightening is uniform and symmetrical.
Common Faults and Troubleshooting Methods
|
Failure |
Reason |
Exclusion method |
|
The valve is not sealing. |
There's a foreign object lodged. |
Remove foreign objects |
|
Sealing pair damaged |
Replace |
|
|
There is a leak at the flange joint. |
Bolts are tightened unevenly. |
Tighten the bolts evenly. |
|
Flange working surface damage |
Trim the flange working surface |
|
|
Gasket damage |
Replace the gasket. |
|
|
The valve cannot be opened or closed. |
Loose or failed transmission components |
Adjust or replace damaged parts. |
|
Insufficient air pressure, severe air leakage |
Inspect and repair the gas supply pipeline. |
|
|
Pneumatic component aging and failure |
Replace the damaged pneumatic components. |
Installation Dimensions and Outline Drawing
|
Model |
DN |
H |
K |
C |
n-M |
|
RDV502-10 |
65 |
290 |
145 |
19 |
4-Φ18 |
|
RDV503-10 |
80 |
290 |
160 |
19 |
8-Φ18 |
|
RDV504-10 |
100 |
315 |
180 |
19 |
8-Φ18 |
|
RDV505-10 |
125 |
350 |
210 |
20 |
8-Φ18 |
|
RDV506-10 |
150 |
315 |
240 |
20 |
8-Φ22 |
|
RDV508-10 |
200 |
290 |
295 |
20 |
8-Φ22 |
|
RDV510-10 |
250 |
365 |
350 |
26 |
12-Φ22 |
|
RDV512-10 |
300 |
380 |
400 |
28 |
12-Φ22 |